Blower

To remove the component:

WARNING: The blower blades rotate at a high speed. Avoid touching the rotating
blades when removing the blower.

NOTE: The power supply is designed so that removing a blower does not adversely affect system
performance. However, do not remove a blower until the replacement blower is available.

1

1

2

To replace the blower:

1. Align the guidepost on the blower with the connector on the power supply.

CAUTION: Do not press on the center section of the blower because this action can
damage the blades. Press only on the outer edge of the blower.

2. Slide the blower into the connector until it locks into place.

3. Be sure the following conditions occur:

— The blower begins operating immediately.

— The power supply/blower assembly LED is green.