Series 9205 Operations Manual Rev A

161

PLC_SET_VAL

Value

Write Location

Option

This opcode will set specially configured values in a slave PLC. Registers to be written to must be

described via the Configurator’s Recipe Management Group Opcode Control interface. The temperature

data is the value to write. The atmosphere data is the Write location. This can be:

Quench SP

Endo SP

Ammonia SP

N2 SP

Methanol SP

Quench Sec

Drain Sec

T.C. Endo SP

T.C. N2 SP

FNC NH3 SP

T.C. Time

PLC Quench SP

Quench Type

The options are: Wait, Wait up, or Wait Down.

PO_INQ

Temperature PO Value

Atmosphere PO Value

Option

The percent output inquiry is used to test the actual percent output of the temperature controller.

The Temperature PO Value is the temperature percent output to test against. The range is -101 (disable) –

100.

The Atmosphere PO Value is the atmosphere percent output to test against. The range is -101 (disable) –

100.

The Option value will determine how the test will conclude. The options are: Wait (Reach within band), Wait

Up (Reach or Exceed the specified values), or Wait Down (Reach or Be Less than the specified values).

The LIMIT opcode immediately following this opcode sets a time limit on the wait.

A BRANCH opcode immediately following this opcode can be used to change the program flow based on the

inquiry results.

PROGST

N/A

N/A

Recipe Number

Recipe Step

Recipe Programmer

This opcode direct the controller to begin a new recipe, at the selected step, in the current 9205's second

programmer. If the PROGST option is the same program number that is executing the PROGST opcode then

PROGST behaves the same as a RESET. The Recipe Number (range=1-300), Recipe Step (range=1-24), and

Programmer (range=2 to the number of programs supported by the 9205 controller) are numerical values

representing the corresponding numbers of the recipe, step, and programmer to which the recipe and step

apply.

Q_TT_AL_SP

N/A

Transfer Time (Seconds)

N/A

This option will set the quench transfer time alarm setpoint.

The Transfer time is entered in seconds. The range is 0.0 – 3276.7.

QTCSET

Temperature Setpoint

N/A

N/A

This is the quench setpoint opcode. The Temperature Setpoint is the setpoint for a quench cycle. The

range is -301 (disable) – 30000.