Instrument start-up, Flash card & flash card reader, Operator interface screen saver – Super Systems 9205 Series User Manual
Page 16: Default status screen, Nstrument, Tart, Lash, Eader, Perator, Nterface
Series 9205 Operations Manual Rev A
15
!
FUNCTION “operator interface” until the Operator Interface can be repaired or replaced. The
laptop needs to be operating a Windows XP or higher with Internet Explorer. The default IP
address is 192.168.0.200. If you are experiencing problems please call (513) 772-0060 and talk
with our computer communications personnel. Secondly, the Ethernet port can be used for
communications to a SCADA software package. Call us at (513) 772-0060 if you are interested in
this option. The third use for the Ethernet Port is the primary communications connection for the
Configurator 2.0 Software.
Instrument Start-up
On power-up, the Operator Interface will display a Microsoft Windows desktop screen for a few
seconds and then switch to the default Status screen.
Flash Card & Flash Card Reader
Never remove the flash card when the Operator Interface is “ON”.
To properly shut down the Operator Interface, press the Menu button on the default status
screen. Once the menu has been displayed, select the
Shutdown
option. At the prompt, press Yes
to shut down the Operator Interface. See the
section for information
on navigating and using the menu system. This will display a conventional Microsoft Windows
screen. Sliding the black switch to the OFF position (located directly over the green power
connector, on the back of the Operator Interface) or removing the 24VDC plug will turn off the
power to the Operator Interface.
Once the Operator Interface is turned off, remove the compact flash card cover at the top or side
of the display unit, exposing the card. Press the black release button or press card in to eject,
and the card will pop out of the slot. To replace the flash card, simply return the card to the slot
making sure that the release button is in its UP position, and replace the flash card cover to its
proper position. To restore power to the unit, move the black switch to the right or ON position or
connect plug.
Operator Interface Screen Saver
The Operator Interface has a default screen saver. It automatically “blanks” the screen after ten
(10) minutes of non-activity. To disengage the screen saver, simply touch the screen and it will re-
appear.
Default Status Screen
The Status Display shows the temperature controller
information as well as any auxiliary analog inputs, the
status of the timer, and an overview of the programmer.
There are five active buttons on the Status Display:
Menu, Chart, Recipe, Loops, and Ack.
•
The Menu button will display the
configuration menu.