Analog Way SMART QUAD - Ref. SQD200 Programmer's Guide User Manual
Page 62
62
Group
Name
CmdResp Description
Read /
Write
Min
Value
Max
value
Default
value
Values
Index #1
Index #2
PSTATUS_FRAME_COUNT
Pn Pn
Number of frames of an animated
logo
Rd
1
255
1
1 = Logo 1
2 = Logo 2
3 = Logo 3
4 = Logo 4
5 = Logo 5
6 = Logo 6
7 = Logo 7
9 = Frame 1
10 = Frame 2
11 = Frame 3
12 = Frame 4
13 = Frame 5
14 = Frame 6
15 = Frame 7
PSTATUS_REFRESH_INTERVAL
Pi
Pi
Time between 2 frames of an
animated logo
Rd/Wr 1
10000 56
Unit = 1ms
1 = Logo 1
2 = Logo 2
3 = Logo 3
4 = Logo 4
5 = Logo 5
6 = Logo 6
7 = Logo 7
9 = Frame 1
10 = Frame 2
11 = Frame 3
12 = Frame 4
13 = Frame 5
14 = Frame 6
15 = Frame 7
LAN
LANENABLE
ne ne
LAN enable
Rd/Wr 0
1
0
0 = Enable RS232 ( disable LAN )
1 = Enable LAN ( disable RS232 )
LANRESET
nr
nr
LAN factory parameters reset
Rd/Wr 0
1
0
Auto reset
LANSTORE
ns
ns
LAN parameters update
Rd/Wr 0
1
0
Auto reset
LANIP
nw nw
LAN devices addresses
Rd/Wr 0
255
192
IP : 0 to 255
0 = Device
1 = Remote
2 = Gateway
0 = IP address
high byte
1 = IP address
mid high byte
2 = IP address
mid low high byte
3 = IP address
low byte
LANPORT
np np
LAN port numbers
Rd/Wr 0
65535 10500
Local port : 10000 à 10999
Remote port : 0 à 65500
0 = Device
1 = Remote
2 = Gateway
LANNETMASK
nk
nk
LAN netmask
Rd/Wr 0
24
8
Number of 0bits from the right