Analog Way SMART QUAD - Ref. SQD200 Programmer's Guide User Manual
Page 51
51
Group
Name
CmdResp Description
Read /
Write
Min
Value
Max
value
Default
value
Values
Index #1
Index #2
PE_CLOSING_DURATION
cD cD
Layer closing transition duration
Rd/Wr 0
255
10
Unit = 1/10s
0 = Current preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4
0 = Background
Frame for output
1
1 = Background
Frame for output
2 in matrix mode
2 = Background
Layer for output 1
3 = Pip 1 Layer
for output1
Background Layer
for output 2 in
matrix mode
4 = Pip 2 Layer
for output1
5 = Pip 3 Layer
for output1 in
quadravision
mode
Pip1 Layer for
output 2 in matrix
mode
6 = Logo 1
7 = Logo 2
8 = Audio Output
1
9 = Audio Output
2
PRESET
CONTROL
TAKE
TK TK
TAKE, Next preset becomes
Current
Rd/Wr 0
1
0
TAKEAVA
TA TA
Available TAKE flag
Rd
0
1
1
TAKEINFO
TI
TI
TAKE information
Rd
0
2
0
0 = 1 shot TAKE
1 = 2 shot TAKE
2 = Sequenced TAKE
TBAR
NT NT TBAR value
Rd/Wr 0
10000 0
Unit = 0,01%
COPY_FROM
Nf
Nf
Source for preset copy
Rd/Wr 0
6
0
0 = Current preset
1 = Next preset
2 = Previous preset
3 = Memory Preset 1
4 = Memory Preset 2
5 = Memory Preset 3
6 = Memory Preset 4