20 Replacement of Parts

Diagram 20.15

Diagram 20.16

11769

➜➜

➜ ➜

Diagram 20.17

TEMPERATURE PRESSURE
RELIEF VALVE

ELECTRICAL
CONNECTION BOX

DOMESTIC HOT WATER
EXPANSION VESSEL

RETAINING
NUT

PIPE
COUPLING

HEX-HEAD
RETAINING
SCREWS
(4OFF)

9649

9657

11770

20.29 Domestic hot water pump, refer to
diagram 20.15.

Before starting refer to the front of Section 20 Important
information.

• Remove the front panel, refer to Section 17.3.

• Lower the control panel, refer to Section 17.5.

• Drain down domestic hot water circuit of boiler only, see
diagram 20.1.

• Remove pump head from pump block by unscrewing and
removing the four hex-head retaining screws, remove and
support pump head to avoid straining electrical cable.

• Remove cover from the electrical connection box.

• Disconnect pump cable from pump.

• Fit replacement pump head.

20.30 Domestic Hot water expansion vessel,
refer to diagram 20.16.

Before starting refer to the front of Section 20 Important
information.

• Remove the front panel, refer to Section 17.3.

• Lower the control panel, refer to Section 17.5.

• Remove R.H. side panel, refer to Section 17.6.

• Drain down domestic hot water circuit of boiler only, see
diagram 20.1.

• Undo pipe coupling on domestic hot water expansion vessel.

• Unscrew and remove domestic hot water expansion vessel
retaining nut.

• Remove domestic hot water expansion vessel.

• Fit replacement domestic hot water expansion vessel.

20.31 Temperature pressure relief valve, refer
to diagram 20.17.

Before starting refer to the front of Section 20 Important
information.

• Remove the front panel, refer to Section 17.3.

• Drain down domestic hot water circuit of boiler only, see
diagram 20.1.

• Undo couplings to remove temperature pressure relief valve.

• Fit replacement temperature pressure relief valve.

20.32 Domestic Hot water expansion valve,
refer to diagram 20.18.

Before starting refer to the front of Section 20 Important
information.

• Remove the front panel, refer to Section 17.3.

• Lower the control panel, refer to Section 17.5.

• Drain down domestic hot water circuit of boiler only, see
diagram 20.1.

• Undo couplings to remove domestic hot water expansion
valve.

• Fit replacement domestic hot water expansion valve.

PUMP HEAD