Triton 30-party meetme conference board, Telephony board installation – AltiGen MAXCS 7.0 Telephony Hardware User Manual
Page 46
Telephony Board Installation
40
Telephony
Hardware
Manual
Triton 30-Party MeetMe Conference Board
Part Number:
ALTI-CONF-30
Specifications
•
Maximum MeetMe conference sessions: 10
•
Maximum conference participants for all sessions: 30
•
Echo cancellation
•
Mute control
•
Announce participant's name when joining or leaving conference
Telephony Board Installation
Setting Physical Board ID
Before you install a telephony board into a system, it is important you set the Board ID
correctly so that the system can recognize the board. You should not have duplicate
Board IDs for the same type of board. There are six different types of boards. Each type
of board has its own set of board IDs.
•
Triton Analog board (ALTI-TTAT-12, ALTI-TTAT-8, ALTI-TTAS-12): ID range 0-15
•
Proton Analog Board (ALTI-P0800): ID range 0-15
•
Triton T1/PRI board: ID range 0-7
•
Triton VoIP board: ID range 0-9
•
Triton Resource board: ID range 0 or 1
•
Triton Meet-Me Conference board: ID 0
Attaching Cables to the Telephony Boards
After all telephony boards are installed to the system, attach the 40-Pin MVIP bus ribbon
cable to the boards.
•
Be careful to make sure pins in the MVIP connector on the board line up with the
sockets on the MVIP cable. Failure to do so may damage the pins and cause voice
quality issues.
•
If an ALTI-TTAS-12 board is installed, you need to attach the power cable to a 4-pin
server power connector and to the board.
Terminating MVIP Bus
No matter what type of boards you have in the system, always terminate both ends of
the CT (MVIP) bus.