Error messages – Industrial Data Systems IDS 430 User Manual
Page 62

IDS 430/433 Users Manual Version 1.0
- 62 -
Error Messages
Error
Description
Err 0
Power on zero error. See parameter 20.
Err 1
Keyboard error. Occurs during power up while a key on the keyboard is being
pressed or one of the remote switch inputs is activated.
Err 2
Restart Trap. The microprocessor accessed nonexistent memory location. Usual
cause is A/C power “glitch” or static electric discharge.
Err 3
Watchdog Time-out. The weight display has not been updated within the watchdog
time-out period. Usual cause is A/C power glitch or static electric discharge.
Err 4
Battery Error. Battery voltage level was below 2 V when the IDS 430/433 was
powered off.
Err 5
Earom memory error. A checksum error has occurred when reading the
configuration earom memory. Check calibration parameters and rewrite the earom
memory. If error continues, replace earom (U12)
Err 5.1
Earom Time-out, unable to write to the earom memory.
Err 6
Ram memory error. A ram memory error has occurred. Replace U5 if error
continues.
Err 7
The A/D converter is “locked up”. Check load cell wiring.
Err 8
Negative deadload error.
Err 9
Count-by error. The entered value is outside the scale count-by set during
calibration.
Err 10
Pushbutton ZERO error.
Err 11
A to D converter not working.
Err 12
Negative deadload. Check loadcell wiring. Enter a deadload offset in configuration
parameter 19.
Err 14
Page Format line length error. The page format output exceeded the maximum
line length.
Err 15
The function selected is locked. Switch 1 (SW1) on the IDS 430/433’s circuit board
locks and unlocks configuration parameters.
Err 16
Scale Basic Stack Overflow.
Err 18
Referenced an invalid function instruction.
Err 21
ID not found.
Err 22
Scale Basic Prompt error.
Err 23
ID memory full.
Error OL Calibration error or scale is over-loaded (above scale capacity).
undEr
Calibration error or scale is under-loaded (below readable weight).