Scale Parameters
No Parameter Name
Default
Max Value
Pas Field Setting
1 Loadcell mv/v
3
4
3
2 Digital filter
9
18
3
3 Display Update Rate
1
200
3
4 Motion delay time
6
250
3
5 Motion band
6
250
3
6 Motion blanks display
0 (no)
1
3
7 Zero tracking delay
0
250
3
8 Zero tracking band
12
250
3
9 Push button zero percent
100
100
3
10 Primary units type
1 (lb)
6(oz)
3
11 Decimal point position
0
4
3
12 Count-by
1
100
3
13 Alternate units type
2 (kg)
6(oz)
3
14 Alt decimal point
1
4
3
15 Alternate count-by
5
100
3
16 Alt conversion factor
45,360
3
17 Full Scale display digits
10,000
120,000
3
18 Over Weight dd
10,200
120,200
3
19 Deadload offset
3
20 Disable Power-On Zero
1
1
3
21 Deadload Factor
3
22 Weight conversion fact.
3
I/O Port Parameters
No Parameter Name
Default
Max Value
Pas Field Setting
23 Serial port 1 mode
4(8N1)
6
2
24 Serial port 1 baud rate
1(9600)
6
2
25 Serial port 2 mode
4(8N1)
6
2
26 Serial port 2 baud rate
1(9600)
6
2
27 TX2 control / Station Id
255
255
1
28 TX2 Data Format
1 (AND)
4
2
29 Printer port select
2 (Com1)
2
2
30 Auto print LF after CR
1 (yes)
1
2
31 End Of Print character
13 (cr)
255
2
32 Print label 32
16 char
2
33 Print label 33
16 char
2
34 Print label 34
16 char
2
84
Print label 84
30 char
2
85
Print label 85
30 char
2
86
Print label 86
30 char
2
87
Print label 87
30 char
2
88
Print label 88
30 char
2
89
Print label 89
30 char
2
90
Print label 90
30 char
2
35 Print code 1
3 codes
2
36 Print code 2
3 codes
2
37 Print code 3
3 codes
2
38 Print code 4
3 codes
2
39 TTL remote control
1 (yes)
1
2