Function 69 diagnostic tests – Industrial Data Systems IDS 430 User Manual
Page 52

IDS 430/433 Users Manual Version 1.0
- 52 -
Function 69 Diagnostic Tests
1. Hold the CLEAR key down and press the ENTER key to enter the configure
mode.
2. Enter CFG 69. The IDS 430/433 prompts “diA xx” where xx is the currently
selected test number. Enter a test number or press the ENTER key to use the
displayed number.
3. The IDS 430/433 begins the selected test. Press the CLEAR key when the
test is complete.
Test #
Hardware Tested
Description
1
Serial Com. Port 1
Display input data.
2
Serial Com. Port 1
Display input error count.
3
Serial Com. Port 1
Transmit data.
4
Serial Com. Port 2
Display input data.
5
Serial Com. Port 2
Display input error count.
6
Serial Com. Port 2
Transmit data.
7
Parallel Port
Transmit data.
8
A/D converter
Display raw conversion data.
9
Ram Memory
Test memory for errors.
10
Display
Turn on all LED’s and display segments.
11
Configuration
Print the EAROM configuration data.
12
Serial Com. Port 1
Transmit/Receive loop-back test.
13
Serial Com. Port 2
Transmit/Receive loop-back test.
See section: Diagnostic Tests for more information on each test.
Function 70 Initialize Operation Parameters to Factory Defaults
Use function 70 to reset the IDS 430/433’s operation parameters to their factory
default values. This function is used to reset the IDS 430/433’s earom when a
new EPROM program is installed. Do NOT use this function unless you are
ready to begin installation from the beginning.
1. Hold the CLEAR key down and press the ENTER key to enter the configure
mode.
2. Enter CFG 70. The IDS 430/433 prompts, “rESEt”. Press the ENTER key to
reset operation parameters or press the CLEAR key to exit without changing
the operation parameters.
3.
NOTE
: enter 10809 when the display prompts, “rESEt” to reset the
calibration factors to the factory defaults.