Industrial Data Systems IDS 430 User Manual
Page 33

IDS 430/433 Users Manual Version 1.0
- 33 -
Parameter 9. Push Button Zero Percent (100)
Enter the percent of full-scale capacity that can be acquired as the zero point
with the ZERO key. 1 = 1%, 2 = 2%, ... 100 = 100%.
Parameter 10. Primary Units Type (1 [lb])
The scale is calibrated in the primary units. The UNITS key is used to toggle the
weight display between primary units and alternate units. Enter the number that
corresponds with the primary units:
0 = UNDEFINED, no units printed
1 = lb
2 = kg
3 = ton
4 = ten
5 = gram
6 = oz
7 = use print label 32 for units
8 = use print code 1 for units
NOTE: when parameter 10 is changed, parameters 13 and 16 must be
programmed.
Parameter 11. Decimal Point Position (0 [no decimal point])
Enter the decimal point position for the primary units display. For example, if the
scale is calibrated x 0.05 the decimal position = 2.
Parameter 12. Count-by (1)
Enter the primary units count-by. For example, if the scale is configured for:
x 0.05
count-by = 5
x 0.2
count-by = 2
x 1
count-by = 1
x 5
count-by = 5
x 50
count-by = 50
Note: the entry for 0.05 and 5 is the same. The decimal point position (parameter
11) differentiates between the count-by 0.05 and count-by 5.
Parameter 13. Alternate Units Type (2 [kg])
Alternate units are the alternate display and print unit of measure that can be
used in addition to the primary units. The UNITS switch on the IDS 430/433’s
keyboard toggles the weight display between primary units and secondary units.
0 = UNDEFINED, no units printed
1 = lb
2 = kg
3 = ton
4 = tne
5 = gram
6 = oz
7 = use print label 32 for units
8 = use print code 1 for units