Function 73 Initialize Function Memory
The initialize function erases function memory and setpoint monitor memory, and
initializes all parameters with password level 1 or 2. 
Function 73 prompts “rs Fn” . Press the Enter key to initialize only or enter a 
number below to activate a built in program. 
 1. Fill to Setpoint. 
2. Checkweigh: Over/Between/Under
3. Weigh-in / Weigh-out
4. Axle Weigh – Short Scale
5. Axle Weigh – Long Scale
6. ID Tare and Total
7. Peak Hold