FS1 Installation and Operation Manual — 51.5 SNMP Trap Port 2
51.5 SNMP Trap Port 2
This parameter determines the SNMP Trap Port used for sending destination #2 trap
messages. UDP Port 162 is the default used for SNMP trap messages. However, if this
port is being used by another protocol or service, you can change the setting by
modifying this parameter.
Note:
The SNMP Trap Port number does not blink when changed (as does the Trap
Destination IP address); if you change the port number and exit the parameter
(moving to another parameter), the port will change immediately as edited.
60.1 Power Supply Alarm
This parameter controls how the FS1 alarm responds to power supply failures. The
default (Normal) is that the alarm will be triggered anytime either of the internal
power supplies fails or is disconnected from a power source (becomes unplugged). If
the FS1 will only be connected to one power cord, you can suppress this alarm.
51.5 SNMP Trap Port 2
Description of Choices
Parameter Adjustments:
variable
Using the
Adjust buttons, select a UDP port for sending FS1 trap messages.
Default: 162
60.1 Pwr Supply Alarm
Description of Choices
Parameter Adjustments:
Normal
(default)
Suppress
Alarm triggers if either internal power supply experiences a failure or is
disconnected from mains power.
Alarm will not be triggered by a power supply failure or disconnection from power.