Wash Pump/Heater Will not Operate
Refer to the previous checklist under the “Facility
Owner / Manager Section” before proceeding to the
following checklist items:
Verify that LED #1 (Power On) is illuminated. If LED #1 is not illuminated, check:
Main power connection and wiring
Fuse inside the control enclosure
Bi-metallic disc switch for water temperature (switch must be closed if water
temperature is below 120°F)
Bi-metallic disc switch for motor temperature (switch must be closed if motor
temperature is below 150°F)
Check to see that the Liquid Level LEDs #3 and #4 are illuminated when the
wash tank is filled to the waterline.
To test the Liquid Levels in the sanitizer tank:
Start the machine before filling the sanitizer tank, the red light will come on
steady and show on the floor. When the sanitizer tank is filled and reaches the
high level the red light goes out.
If either one or both of the lights are not illuminated or the red beacon acts
different than described above:
Clean the liquid level sensors as described in the “Preventive Maintenance”
section of this manual.
Be sure that all connections to and from the Liquid Level sensors are secure and
that there is no physical damage to the wiring.
If damage to connectors and/or wiring is found, contact Power Soak Systems,
Inc. at 800-444-9624.
If the above troubleshooting guidelines do not correct the problem, it will be
necessary to contact Power Soak Systems, Inc. at 800-444-9624.