Daily, Monthly, As needed – Power Soak 33755 PS-225 Owner's Manual User Manual
Page 24

20
Your system requires minimal, routine preventative maintenance. As such, the
following should be done on a routine basis to ensure that your system remains
reliable:
Daily
Clean the liquid level sensors. These sensors are located on
the side walls of the wash and sanitizer tanks. They are the
white plastic discs with metal centers. Clean the sensor faces
thoroughly. If cleaned regularly, a washcloth and soapy water
are all that is required.
Monthly
Clean the pump motor fan shroud with a damp, soapy
cloth. The motor shroud is the "vented" cover located at
the end of the motor (closest to the control panel). This
will prevent grease and dust from accumulating in the
cover's openings, which can obstruct the airflow that
cools the motor.
As needed
De-lime the wash tank. Simply add a recommended titration of de-liming agent
to a tank of warm, fresh water and run the system overnight. Ask your chemical
sales representative to recommend a specific de-liming agent.
If the liquid level sensors are not cleaned regularly, the
machine may fail to operate; or it may be possible to
run it without water, which may cause serious damage
to the unit. Running the system without water in the
wash tank may cause damage that is not covered by
warranty.
IMPORTANT: Turn off the power to the unit at the main
breaker prior to performing the following task!