2 changing the default settings – IEI Integration SRM_121_150 v3.00 User Manual
Page 70
SRM Series/SRM-KIT Series Monitor
Page 60
The Figure 6-5 shows the SRM-121 default linearity of the LCD backlight and ambient
light. When the sensor detects the ambient illuminance as 5200 LUX or above, the SRM
series industrial monitor adjusts the LCD brightness to 100%.
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
100%
100%100%
100%100%
0
100
200
300
400
500
600
700
800
900
1000
0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
10000
15000
20000
25000
30000
35000
40000
Ambient Light (LUX)
LCD Brightness (cd/m2)
Figure 6-5: SRM-121 Default Linearity of the LCD Backlight and Ambient Light
6.2.4.2 Changing the Default Settings
The maximum and minimum LUX value and backlight brightness in the OSD panel can be
adjusted to meet custom needs and lighting conditions.
NOTE:
When the auto dimming function is on, the “Brightness Control” in main
display feature (refer to Section 6.2.1) is not effective. The user can only
adjust the maximum and minimum value of the LUX and backlight to make
the LCD brighter or darker.
Light Max. and Light Min.
To keep the LCD brightness within a specific range, not the 0~100% wide range, adjust
the minimum and maximum value of the LCD backlight. For example, set the Light Min. to