6.2.4 Auto-Dimming Configurations
The SRM industrial monitor features an auto-dimming LCD that can automatically adjust
the backlight brightness according to the ambient light. If the auto-dimming function is
turned on, the backlight turns brighter when the ambient illuminance is high. The backlight
dims automatically when the ambient brightness level is low.
The SI unit of illuminance is “lux”. Lux measures the intensity of light. Table 6-2 lists the
illuminance (LUX measurement) of everyday light sources.
Light Source
Brightness (LUX)
Night without moonlight
<10
Night with moonlight
<100
Office desk lighting
500~1000
Overcast day
1000~2000
Sunny day
10,000
Direct sunlight
100,000
Table 6-2: LUX Measurement of Everyday Light Source
6.2.4.1 Default Settings
The auto-dimming default settings of the SRM industrial monitor are listed in the table
below:
OSD
Default Settings Description
Light Min 0
Minimum backlight value
Unit in percentage (%)
Light Max 100
Maximum backlight value
Unit in percentage (%)
LUX Min
0
Minimum ambient brightness
Unit in 100 lux
LUX Max 52
Maximum ambient brightness
Unit in 100 lux (52=5200 lux)
Table 6-3: Auto-Dimming Default Settings