Windows NT Specific Error Messages and Diagnostics

ANA-5910/5930/5940 User’s Guide
Stock Number: 510694-00, Rev. C

Page: B-13

Print Spec Number: 493081-00
Current Date: 5/28/97

ECN Date: 05/29/97

7

Execute the extended SAR memory test by entering the
following command from the ADM:0> prompt:

ADM:0> sar_mem_e

Extended Segmentation and Reassembly Tests
PASSED

8

To execute an optional external test, follow these steps:

a

Remove the ATM cable from the adapter’s ATM connector
(if one is already connected).

b

Place an external ATM loopback cable on the adapter’s ATM
connector. Obtain this cable from your cable vendor.

c

Test the external ATM connection to the adapter by entering
the command from the ADM:0> prompt:

ADM:0> atm_external

ATM External Tests
PASSED

d

Remove the loopback cable and reconnect the adapter to
your ATM switch.

9

Exit the diagnostic program:

ADM:0> quit

10

If all the diagnostic tests passed, restart the drivers you need.