Diagnostics Error Messages

Diagnostic error messages appear at the command line when
running the

aatmdiag.exe

program.

ioctl link failure

An error was encountered while doing
I_PLINK or I_PUNLINK between

aarp.sys

,

and

atmo.sys

drivers.

Value out of
bounds

The value in the configuration file is out of
bounds.

Diagnostic Error Message

Description

Error: Invalid loop
count entered. Must be
positive integer number

A negative or zero loop count is invalid for
the

loop

command.

Error: Unable to setup
diagnostics. Check if
atmo driver is busy

The driver is busy; several possible causes are
listed below:
Another application is using the

atmo.sys

driver (another

aatmdiag.exe

is currently

active). Terminate the application using the

atmo.sys

driver. For Classical IP, use

acipcnfg.exe

. For an active ARP, use

net stop aarp

.

An invalid controller number was specified
while invoking aatmdiag -c #. Valid controller
numbers range from 0 to N, where N is equal
to the total number of physical boards in the
system minus 1. Only one adapter is
supported in a system at this time (enter 0).
The

atmo.sys

driver was not loaded properly.

Reconfigure the driver or reinstall the driver.

SYSTEM Error: No such
file or directory File: X

The file does not exist when using the aatmdiag
-f X

option. Make sure this file exists.