beautypg.com

Ks series – General Pump KS Repair Manual User Manual

Page 9

background image

GENERAL PUMP

A member of the Interpump Group

KS SERIES

Page 9

Ref 300902 Rev.A

07-12

2.1.4 Disassembly of the reducer unit

Remove the fastening screws of the reducer case cover.

In the appropriate holes, position and screw on 3 threaded dowels or M8 screws (1, fig. 13) using in the

function of extractors; simultaneously, hammer on the pinion so that the bearing remains attached when

extracting the cover. (fig. 14).

Remove the reducer case cover and extract the bearing from the pinion using standard tools (fig. 15).

Remove the ring gear fastening screws with the related washer, and extract the ring gear. If necessary, use a

slide hammer applying it to two M8 holes (1, fig. 16) or standard extraction tool (fig. 16).

Remove the pinion using a slide hammer applying it to the M12 hole (fig. 17).

Unfasten the reducer case screws; then remove the reducer case (fig. 18).