The bearings and the ring gear may be mounted at room temperature. the driving operation could be

facilitated by heating the interested parts to a temperature ranging between 250

o

-300

o

F (120

o

-150

o

C),

being sure that the ring nuts fit thoroughly into their seats.

Insert the O-ring gasket in the appropriate seat of the reducer case (fig. 25).

Position the reducer case on the pinion bearing; use two screws or two M8 threaded dowels to maintain the

cover in position during the subsequent assembly operation (1, fig. 26).

Assemble the reducer case cover using a stopper pressing against the surface of the cover, or use the appro-

priate tool part #F27517400 (fig. 26a). Facilitate the operation by simultaneously fastening some of the

screws (2, fig. 26).

Page 11

Ref 300902 Rev.A

07-12

Fasten the reducer case cover with the 10 screws M8x50 and calibrate the screws using a torque wrench

(fig, 27) as indicated in paragraph 3.