If the extraction of the delivery and suction valve units is particularly difficult (for example due to

incrustations caused by prolonged pump inactivity), use the extraction too part #F27516900

combined with the tool part #F26019400.

Page 14

Ref 300902 Rev.A

07-12

Disassemble the suction and delivery valve units by screwing

on an M10 screw long enough to act on the valve and extract the

valve guide from the valve seat (1, fig. 33).

2.2.2 Head assembly - valve units

Pay careful attention to state of wear of the various components; replace them when necessary,

and in any case within the intervals indicated in the table in fig. 14, chapter 11 of the Owner’s

Manual. At each valve inspection, replace all valve plugs, O-rings and anti-extrusion rings.

Before positioning the valve units, clean and perfectly dry the relevant seats in the head as

indicated in fig. 34.