3. SCREW CALIBRATION
Screws are to be fastened exclusively using a torque wrench.
Description
Exploded View
Position
(From Owner’s Manual)
Fastening
Ft. Lbs.
Fastening
Nm
Cover Fastening Screws
9 and 10
7.4
10
Plunger Fastening Screws
33
14.8
20
Connecting Rod Fastening Screws
21
28
38*
Head Fastening Screws
43
88.5
120**
Valve Cover Screws
45
88.5
120***
Lifting Bracket Fastening Screws
20
73.8
100
Oil Discharge Plug
11
29.5
40
Delivery Duct Plug
57
29.5
40
Reducer Case and Cover
Fastening Screw
68
29.5
40
Ring Gear Fastening Screw
71
51.6
70
* The connecting rod fastening screws must be fastened simultaneously respecting the phases
indicated on page 6.
** The head fastening screws, exploded view position 43, must be tightened with a torque wrench,
lubricating the threaded stem.
*** The valve cover fastening screws, exploded view position 45, must be tightened with a torque
wrench, lubricating the threaded stem and respecting the order indicated in the scheme in
fig. 43