beautypg.com

Connections – Niles Audio A4.6Ci User Manual

Page 39

background image

TERMINATING FOUR-PAIR TWISTED CABLE
The Solo

and Select

Master Keypad Modules, the expander, and the A4.6Ci’s system-expansion connections

require a four-pair twisted cable with a one-to-one wiring configuration. To maintain consistency throughout
all Intellipad

®

Ci installations, we recommend the color-coding pattern described in Figure 31. However, you

may follow the color-coding pattern of your choice, as long as it is consistent throughout the system.

39

CONNECTIONS

1 2 3 4

Pair 2

Pair 1

T568A

Pair 3

Pair 4

5 6 7 8

1

= Green/White

2

= Green

3

= Orange/White

4

= Blue

5

= Blue/White

6

= Orange

7

= Brown/White

8

= Brown

Figure 31

Solo

Master

Keypad Module

Numeric

Accessory

Keypad Module

RJ-45 Connector for
connection to Master
Keypad Module

RJ-45 Connector
for connection to
Numeric

Accessory

Keypad Module

RJ-45 Connector
for connection to
IR Sensors

RJ-45 Connector for

connection to

the ZR-4630

Included

Jumper Cable

IR SENSOR

INPUT

OUTPUT

SYSTEM

ACCESSORY

KEYPADS

Figure 32

Figure 33

CONNECTING
NUMERIC

KEYPADS

Each Solo

and Select

Master Keypad

Module can be mated with one
optional Numeric

Accessory Keypad

Module using an included jumper
cable (see Figure 33).

CONNECTING THE SOLO

AND SELECT

MASTER KEYPADS TO

THE HOME RUN OF FOUR-PAIR TWISTED CABLE
The home run of four-pair twisted cable is terminated with a male
RJ-45 connector and plugged into the rear-panel jack labeled SYS-
TEM on the Solo

and Select

Master Keypad Module (see Figure 32).