beautypg.com

Appliance location and clearances, Warning, Caution – Hearth and Home Technologies Direct Vent Room Heater 839-1460 User Manual

Page 7

background image

September 1, 2008

Page 7

Quadra-Fire · Sapphire · 250-7233H

3

Appliance Location and Clearances

A. Selecting Appliance Location

NOTE:

·

Illustrations reflect typical installations and are FOR

DESIGN PURPOSES ONLY.

·

Illustrations/diagrams are not drawn to scale.

·

Actual installation may vary due to individual design

preference.

When selecting a location for your appliance it is important to
consider the required clearances to walls (see Figure 3.1).

Figure 3.1

WARNING

Fire Risk
Provide adequate clearance:
• Around air openings
• To

combustibles

• For service access
Locate appliance away from traffic areas.

Fire Risk.
Locate and install appliance to all

clearance specifications in manual.

WARNING

B. Clearances

Model

A

B

C

D

E

F

G

Sapphire

Inches

6

3

1

54

36

36

23

Millimeters

152

76

25

1372

914

914

584

NOTE: Flooring beneath appliance may reach 90 degrees
plus room ambient temperature. Check with flooring
manufacturer for maximum temperature allowed on flooring
surfaces.

It is permissable to place the appliance on carpet.

CAUTION

Some carpet materials may be sensitive to radiant heat from the
appliance causing discoloration or odor.

Fire Risk.
Odor Risk.
Tipping Risk
• Install appliance on a stable, level platform/

floor strong enough to support appliance
without tipping.

• USE wood flooring, ceramic tile, brick hearth

or high pressure laminate flooring applied
directly over the sub-flooring material.

WARNING

A

E

A

B

F

A

D

G

C

C

A

NOTE: For actual appliance dimensions refer to Section
12.