Venting – Harman Stove Company HARMAN P68 User Manual
Page 13

13
P68 Pellet Stove
3-90-00688R24_06/13
#8 installing through the ceiling
Through the ceiling vent, follow PL vent manufacturers
recommendations when using wall and ceiling pass throughs.
note: do not place joints within wall pass-throughs.
M i n i m u m f l u e v e n t
configuration
It is recommended that outside
air be installed with this venting
configuration to reduce smoke
and creosote smell in the room in
the event of power failure.
Min. above ground level
12"
venting
Fig. 15
Fig. 14
PL vent manufacturer's
firestop spacer and
support
(See Page 7 for
corner installation
clearances)
Storm collar
Flashing
3" min.
3" min.
12" min.
3" min.
3" min.
No insulation or
other combustible
materials are allowed
within 3" of the pellet
vent pipe. Unless
specified by the pipe
manufacturer
12"
min. wall to outlet
36"
min. clear
anc
e to an
y
combustable ma
terial
Fig. 16