System LEDs and internal health LED combinations

When the internal health LED on the front panel illuminates either amber or red, the server is experiencing
a health event. Combinations of illuminated system LEDs and the internal health LED indicate system
status.
The front panel health LEDs indicate only the current hardware status. In some situations, HP SIM may
report server status differently than the health LEDs because the software tracks more system attributes.

System LED and
Color

Internal Health
LED Color

Status

Processor failure
(amber)

Red

One or more of the following conditions may exist:

Processor has failed.

Processor is not installed in the socket.

Processor is unsupported.

ROM detects a failed processor during POST.

Amber

Processor is in a pre-failure condition.

DIMM failure, slot X
(amber)

Red

DIMM in slot X has failed.

DIMM in slot X is an unsupported type, and no valid
memory exists in another channel.

Amber

DIMM in slot X has reached the single-bit correctable
error threshold.

DIMM in slot X is in a pre-failure condition.

DIMM in slot X is an unsupported type, but valid
memory exists in another channel.

DIMM failure, all slots
in one channel
(amber)

Red

No valid or usable memory is installed in the system.

Amber

The entire channel is not populated.

DIMMs do not match within the channel, but other
valid memory is available.

Overtemperature
(amber)

Amber

The Health Driver has detected a cautionary temperature
level.

Red

The server has detected a hardware critical temperature
level.

Fan module (amber)

Red

The minimum fan requirements are not being met in one or
more of the fan modules. One or more fans have failed or
are missing.

Power supply (amber) Red

One or more of the following conditions may exist:

There is no AC power.

The power supply has failed.

Amber

There is a power supply mismatch at POST.