beautypg.com

7 grounding equipment and methods, 7 grounding equipment and methods –6 – HP zt3000 User Manual

Page 89

background image

4–6

Maintenance and Service Guide

Removal and Replacement Preliminaries

4.7 Grounding Equipment and

Methods

Grounding equipment must include either a wrist strap or a foot
strap at a grounded workstation.

When seated, wear a wrist strap connected to a grounded
system. Wrist straps are flexible straps with a minimum of
one megohm ±10% resistance in the ground cords. To
provide proper ground, wear a strap snugly against the skin
at all times. On grounded mats with banana-plug connectors,
use alligator clips to connect a wrist strap.

When standing, use foot straps and a grounded floor mat.
Foot straps (heel, toe, or boot straps) can be used at standing
workstations and are compatible with most types of shoes
or boots. On conductive floors or dissipative floor mats, use
foot straps on both feet with a minimum of one megohm
resistance between the operator and ground. To be effective,
the conductive strips must be worn in contact with the skin.

Other grounding equipment recommended for use in preventing
electrostatic damage includes:

Antistatic tape

Antistatic smocks, aprons, and sleeve protectors

Conductive bins and other assembly or soldering aids

Nonconductive foam

Conductive tabletop workstations with ground cords of
one megohm resistance

Static-dissipative tables or floor mats with hard ties to
the ground

Field service kits

Static awareness labels

Material-handling packages

Nonconductive plastic bags, tubes, or boxes

325388-002.book Page 6 Friday, October 24, 2003 9:21 AM