beautypg.com

Test and adjustment – Heath Zenith Motion Sensor Light Control 5408 / 5410 User Manual

Page 3

background image

3

598-1303-01

Align the light control cover plate and the junction

box holes. Secure with the mounting screws.

If not installed on a weatherproof box or if an adaptor

plate (not included) was used,

caulk the wall plate

and mounting surface with silicone.

Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180°
from the factory setting. When screwing in the flood-
lamps, do not overtighten.

Keep lamps at
least 1" (25 mm)
from the sensor.

Avoid water damage and
electrical shock - keep lamp
holders below horizontal.

Lock nuts

M

ount

the

L

ight

C

ontroL

To Deactivate the Flash Alert

Remove the light fixture if necessary.

Locate the (Blue) wire loop coming from the sensor

inside the canopy.

Cut the (Blue) wire loop.

Securely attach wire nuts (supplied) to each of the

cut ends of the (Blue) wire.

DO NOT connect the

wires together.

Mount light control to wall or eave.

WARNING: Turn power off at circuit breaker

or fuse.

Bottom of Sensor

ON-TIME

10 5 1 TEST

MIN MAX

SENS

TEST AND ADJUSTMENT

NOTE: Sensor has a 1

1

/

2

minute warm up period

before it will detect motion. When first turned
on, wait 1

1

/

2

minutes.

Turn on the circuit breaker and light switch.

Turn the SENSITIVITY (SENS) control to the mid posi-

tion and the ON-TIME control to the TEST position.

Flash Alert - Deactivated

(Blue)