Room temperature Mode: This setting, see above,

will produce a room temperature of 70 degrees with the

distribution blower at medium speed.

Room temperature Mode

The P43 is a fully automatic stove that features two

operating modes; Stove Temperature Mode and Room

Temperature Mode. In Stove Temperature Mode, you

select a burn rate and the stove will remain at the same

burn rate regardless of the room temperature.

In the Room Temperature Mode the stove constantly

monitors the temperature in the room and adjusts the

size of the fire and the heat output of the stove so that

the room is kept at a constant temperature. Room

mode, in the AUTO position, has the added advantage

of turning the stove off if no heat is required and turning

the stove on again when the room temperature drops

below your desired room temperature.
Room temperature Mode

Most consumers use the stove in the Room Temperature

Mode because it is the easiest and most efficient

method of keeping the room at a given temperature. In

the Room Temperature Mode, the Room Sensing Probe

constantly monitors room temperature. As the weather

changes outside and your home needs varying amounts

of heat to be at a desired temperature, the stove will

automatically increase fire size and heat output so

that a constant even temperature is maintained. If the

weather warms up and no heat is required, the stove

will gradually shut down. When the house cools down,

the stove will automatically bring the room temperature

to the precise temperature you desire.

In the Room Temperature Mode you can select either

Auto or Manual modes for the igniter, using the igniter

toggle switch. When the toggle switch is in the Auto

position, the igniter, located inside the burn pot, is ready

to automatically light the fire when required. When the

toggle switch set to the Manual position the stove can

be lit manually with either a gel or a wax type fire starter.

(see lighting instructions on page 19.) With the igniter

toggle switch set in the Manual position the stove will

automatically adjust heat output, but the stove will not

automatically shut down if no heat is required. Instead

it will go to its lowest setting and remain there. The

Manual position on the igniter toggle switch lets you

light the stove manually, should the igniter fail for any

reason. Secondly if you are using the Harman battery

back up system, the Manual setting will prevent the

stove from turning off and on during a power failure,

which would drain the back up battery.

In the Room Temperature Mode, the distribution blower

speed can be increased or decreased by adjusting the

Room Temp/Off/Stove Temp dial between L and H. As

output of the stove increases, the speed of the blower

will increase automatically to insure that more heat is

transferred out into the room. The distribution blower

will shut off as the room reaches the set temperature,

this will prevent overheating of the room.

cautiOn:

DO

nOt CONNECT TO ANY AIR DISTRIBUTION

DUCT OR SYSTEM.

DO

nOt BURN GARBAGE OR FLAMMABLE

FLUIDS SUCH AS GASOLINE, NAPTHA, OR

ENGINE OIL.

HOT WHILE IN OPERATION. KEEP CHILDREN,

CLOTHING, AND FURNITURE AWAY. CONTACT

MAY CAUSE SKIN BURNS.

KEEP FIREBOX AND ASH REMOVAL DOORS

CLOSED DURING OPERATION. MAINTAIN

SEALS IN GOOD CONDITION.