P43 Pellet Stove

3-90-04301R18_03/13

#6 Installing into an existing fireplace

chimney

This method provides excellent venting for normal

operation. This method also provides natural draft in

the event of a power failure.

In some places in the US and Canada it is required

that the vent pipe extend all the way to the top of the

chimney. The pipe or liner inside the chimney should

be 4" diameter.

In this method a cap should also be installed on the

chimney to keep out rain. Be sure to use approved

pellet vent pipe fittings. Seal pipe joints with silicone or

aluminum tape in addition to the sealing system used

by the manufacturer. Pipe size should be increased to

4" using this method.

#7 installing into an existing chimney

This method provides excellent venting for normal

operation. This method also provides natural draft in

the event of a power failure.

In some places in the US and Canada it is required

that the vent pipe extend all the way to the top of the

chimney. The pipe or liner inside the chimney should

be 4" diameter.

In this method a cap should also be installed on the

chimney to keep out rain.

Fig. 12

Fig. 13

venting