P43 Pellet Stove

3-90-04301R18_03/13

P43 automatic ignition eSP control

Feed adjuster

Sets the maximum

feed rate.

Test

Runs all motors at full

speed for one minute

to check operation.

Afterward the control

will simulate a

minimum burn and the

combustion blower will

remain on low.

Igniter switch

Set to appropriate

Start-Up mode.

Distribution Blower

speed adjustment

range.

L = low

H = high

Variable speed

anywhere between L

and H; although as the

stove temp. goes up ,

so does the low end of

the scale.

Temp dial

Allows you to adjust the room temperature in Room

Temp Mode using the outer scale marked in degrees

Fahrenheit. It also allows you to adjust the stove

temperature while in Stove Temp Mode using the inner

scale marked from 1 to 7.

Mode Selector

Allows you to choose between

Room Temp Mode, Stove Temp

Mode, or OFF. Also allows you

to vary the distribution blower

speed by turning the knob to the

high or low side of each mode.

Power Light

Indicates power to the

control.

Indicates power to the

feed motor.

Indicates power to the

igniter.

Indicates power to

combustion blower.

Status Light

Will be lit in either stove

or room temp mode

when pointer is not

within off position band

except after normal shut

down. Blinks to indicate

errors listed below.

Indicates power to

distribution blower.

Status light error messages:
3 blinks:
Indicates that the ESP (Exhaust Sensing

Probe) has gone out of range too many times in a

specified time. Perform a manual reset*, If the code

returns immediately, the ESP may be damaged or

disconnected. Otherwise, the exhaust system may

need cleaned.

4 blinks: Can occur only in Room Temp Mode and

indicates Room Sensing Probe failed or not installed.

If a Room Sensing Probe is then installed, the status

light will automatically reset.

5 blinks (in igniter auto. Mode Only): Indicates that

the unit has failed to light within the 36 minute start

cycle. To reset - Turn Mode Selector to "OFF", then turn

to either mode again.

6 blinks : Indicates that the control has calculated poor

or incomplete combustion occurring for more than 50

minutes.

A six blink status may be set if the stove is allowed to

run out of pellets. To reset, turn mode selector to "OFF"

then back on to the desired mode. If the unit was not

out of pellets, see Troubleshooting section, Page 27,

for more details.

* Manual reset- disconnect power cord for a few

seconds and reconnect. If error still occurs call your

Dealer.