beautypg.com

7 license requirements, 8 recommendations for ifr approval, 3 nav / gps switching – Honeywell BENDIX/KING KLN 94 User Manual

Page 23: 4 right angle connector, 1 aircraft logbook entry, 2 aircraft installation requirements

background image

B

KLN 94

Rev. 4, Jan/2003 10599I04.CDL

Page 1-13

1.6.3 NAV/GPS Switching

Installations in which the outputs from a KLN 94 and an existing navigation system are being
switched onto a common indicator will require some remote relay switching that is controlled by
the NAV/GPS switch/annunciator.

1.6.4 Right Angle Connector

The part number for a right angle connector for the KA 91 or KA 92 antenna connection is
030-00134-0001. This right angle connector was originally an option but has been included in the
installation kit as the standard connector.

1.7 LICENSE REQUIREMENTS

None.

1.8 RECOMMENDATIONS FOR IFR APPROVAL

1.8.1 Aircraft Logbook Entry

1.8.2 Aircraft Installation Requirements

NOTE

For the following subsections, refer to

Section 1.5

and

Section 1.6

for allowable configurations where applicable. Refer to

Section II

for

illustrations.

1.8.2.1 TSO/JTSO’d Antenna

The antenna must be a TSO/JTSO’d KA 91, P/N 071-01545-0200 or KA 92 P/N
071-01553-0200. If the P/N of the KA 91 is not available, it may be identified by the serial number
as the TSO/JTSO’d antennas have a five digit serial number.

1.8.2.2 Nav Instrumentation

The navigation information (D-Bar, Nav Flag, and To-From) must be displayed on an instrument
in the pilot’s panel. Electromechanical indicators are capable of displaying the variable scale
factors of enroute, terminal, and approach modes.

1.8.2.3 OBS Interface

The use of an OBS resolver will reduce pilot workload during an instrument approach. It allows
the OBS setting to be changed on the navigation indicator when the KLN 94 is operating in the
OBS mode. Without the OBS resolver connection, the OBS may be changed from the KLN 94
controls. OBS mode is commonly used during procedure turns and holding patterns.

Some certification agencies may require the use of the OBS resolver for approach certification.
Consult your approval agency for additional information. Refer to

Section 1.3

and

Section 2.3.6