Honeywell SERIES COMMUNICATING TB7600 User Manual
Page 7

TB7600 SERIES COMMUNICATING RTU/HEAT PUMP THERMOSTATS
7
62-2016—01
Fig. 8. Wiring example of single remote wall mounted room sensor
Fig. 9. Wiring examples of two remote wall mounted room sensors for averaging applications
Fig. 10. Wiring examples of three remote wall mounted room sensors for averaging applications
TB-MA-1014 MIXED AIR TEMPERATURE SENSOR WITH JUNCTION BOX.
This sensor can be used for:
• Remote return air temperature sensing with the sensor mounted on the return air duct.
• Outside air temperature sensing with the sensor installed in the fresh air plenum.
• Supply air temperature sensor
TB-ODA-1014 OUTDOOR AIR TEMPERATURE SENSOR
This sensor can be used for:
• Outside air temperature sensing with the sensor installed directly exposed to the elements.
• Sensor uses a water resistant NEMA 4 ABS enclosure for outdoor applications
Fig. 11. Wiring for TB-MA-1014 and TB-ODA-1014 Sensors
Scom
RS
AU
C
D1
Scom
RS
AUX
C
DI
Scom
RS
TB7600 SERIES
THERMOSTAT
TB7600 SERIES
THERMOSTAT
TB-WALLOVR-1014
TB-WALL-1014
DIP SWITCHES
S1 = ON S2 = ON
DIP SWITCHES
S2-1 = ON S2-2 = ON
ON
1 2
S2
DIP SWITCHES
S2-1 = ON S2-2 = ON
ON
1 2
S2
REMOTE WIRING 1 SENSOR
M16996
DIP SWITCHES
S1 = ON S2 = ON
D2
Scom
RS
AU
C
D1
D2
EITHER D1 OR D2 CAN BE USED ON THE TB7600 FOR CONNECTION FROM THE DI ON THE WALL MODULE WITH OVERRIDE.
1
1
Scom
RS
AUX
C
DI
Scom
RS
TB-WALLOVR-1014
TB-WALL-1014
DIP SWITCHES
S1 = OFF
S2 = ON
DIP SWITCHES
S2-1 = OFF
S2-2 = ON
ON
1 2
S2
DIP SWITCHES
S2-1 = OFF
S2-2 = ON
ON
1 2
S2
DIP SWITCHES
S1 = OFF
S2 = ON
REMOTE WIRING 2 SENSORS
M16997
Scom
RS
TB-WALL-1014
Scom
RS
TB-WALL-1014
TB-WAL-1014 AND TB-WALLOVR-1014 CAN BE MIXED AND MATCHED
TB-WAL-1014 AND TB-WALLOVR-1014 ARE TO BE WIRED IN PARALLELL
ENSURE THE DIP SWITCH SETTING IS CORRECT IN EACH REMOTE SENSOR
1
1
Scom
RS
AUX
C
DI
TB-WALLOVR-1014
DIP SWITCHES
S1 = OFF
S2 = ON
DIP SWITCHES
S2-1 = OFF
S2-2 = ON
ON
1 2
S2
Scom
RS
AUX
C
DI
TB-WALLOVR-1014
Scom
RS
AU
C
D1
TB7600 SERIES
THERMOSTAT
D2
Scom
RS
AU
C
D1
TB7600 SERIES
THERMOSTAT
D2
Scom
RS
AU
C
D1
TB7600 SERIES
THERMOSTAT
D2
DIP SWITCHES
S1 = OFF
S2 = ON
DIP SWITCHES
S1 = OFF
S2 = ON
DIP SWITCHES
S1 = OFF
S2 = ON
EITHER D1 OR D2 CAN BE USED ON THE TB7600 FOR CONNECTION FROM THE DI ON THE WALL MODULE WITH OVERRIDE.
2
2
2
Scom
RS
AUX
C
DI
TB-WALLOVR-1014
DIP SWITCHES
S1 = OFF
S2 = OFF
DIP SWITCHES
S1 = OFF
S2 = OFF
DIP SWITCHES
S2-1 = OFF
S2-2 = OFF
ON
1 2
S2
DIP SWITCHES
S1 = OFF
S2 = OFF
DIP SWITCHES
S1 = OFF
S2 = OFF
REMOTE WIRING 3 SENSORS
M16998
Scom
RS
TB-WALL-1014
Scom
RS
TB-WALL-1014
DIP SWITCHES
S2-1 = OFF
S2-2 = OFF
ON
1 2
S2
Scom
RS
TB-WALL-1014
Scom
RS
AU
C
D1
TB7600 SERIES
THERMOSTAT
D2
Scom
RS
AU
C
D1
TB7600 SERIES
THERMOSTAT
D2
Scom
RS
AUX
C
DI
TB-WALLOVR-1014
Scom
RS
AUX
C
DI
TB-WALLOVR-1014
EITHER D1 OR D2 CAN BE USED ON THE TB7600 FOR CONNECTION FROM THE DI ON THE WALL MODULE WITH OVERRIDE.
1
1
1
REMOTE WIRING 1 SENSOR
REMOTE WIRING 4 SENSORS
Scom
RS
Scom
MS
Scom
OS
OR
OR
10 K SENSOR
Scom
RS
Scom
MS
Scom
OS
OR
OR
10 K SENSOR
10 K SENSOR
10 K SENSOR
10 K SENSOR
M16999