Honeywell PROGRAMMABLE THERMOSTAT 8160 User Manual
Description, Installation
08060 / TH106 / TL6061
69-2202-04 2010-04-06 1/4
Programmable Thermostat - Installation and User Guide
*
LP appears only for the first two minutes when the thermostat is without power. This
can occur during a power outage or when the thermal protection device inside the base-
board heater is opened.
This programmable thermostat can be used to control an electric
heating system such as an electric baseboard heater, a radiant ceil-
ing, a radiant floor, a convector or a fan-forced heater.
The thermostat cannot be used with:
•
a resistive load over 16.7 A
•
a resistive load under 2 A
•
a system driven by a contactor or relay (inductive load)
•
a central heating system
SUPPLIED PARTS:
•
One (1) thermostat
•
Two (2) 6-32 screws
•
Two (2) solderless connectors
TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRICAL SHOCK. THE INSTAL-
LATION MUST BE PERFORMED BY AN ELECTRICIAN.
All cables and connections must conform to the local electrical
code.
Special CO/ALR solderless connectors must be used when con-
necting with aluminum conductors.
Install the thermostat onto an electrical box.
Install the thermostat about 5 feet high, on an inside wall facing
the heater.
Avoid locations where there are air drafts (such as the top of a
staircase or an air outlet), dead air spots (such as behind a
door), or direct sunlight.
Do not install the thermostat on a wall that conceals chimney or
stove pipes.
The thermostat wires are not polarized; either wire can be con-
nected to the load or to the power supply.
NOTE:
Always keep the thermostat's vents clean and unobstructed.
n
o
Connect the thermostat wires to the line wires and to the load
wires using solderless connectors for copper wires.
p
Push any excess wire back into the electrical box.
NOTE:
If necessary, before re-installing the front component, config-
ure the thermostat (see section 3).
q
Return power to heating system.
n
Description
1.
o
Installation
2.
Select the mode
of operation
Set the time
Time and day
Temperature
Indicates the current
mode of operation
Skip a period
Program the schedule
Temperature
preset icon
Temperature
adjustment
buttons
Temperature
preset buttons
Indicates the
heating power
Indicates the current
period (appears in
automatic mode only)
Indicates that the
temperature setpoint
is displayed
Set the day
Indicates that the
thermostat is configured
for a fan-forced heater
Indicates that the ther-
mostat is without power *
Indicates that the
settings are locked
2-wire installation
4-wire installation
08160
TH106
TL6160
400-106-023-F_69-2202-04 (TH106-03 Honeywell TL6160A1004 Cadet 08160) ENG.fm Page 1 Tuesday, April 6, 2010 2:40 PM