Tb7600 series model selection, Heat pump model specific features – Honeywell SERIES COMMUNICATING TB7600 User Manual
Page 2

TB7600 SERIES COMMUNICATING RTU/HEAT PUMP THERMOSTATS
62-2016—01
2
• Remote discharge air sensor input
• Automatic frost protection to prevents costly freeze damage
• Anti short cycle and minimum on/off run time protection to reduce wear and maximizes life span of
mechanical equipment
• Two programmable digital inputs for added flexibility can be use to monitor filter status, activate a remote
temporary occupancy switch, and/or used as a general purpose service indicator
• 7 day programmable models, 2 or 4 events for use in non-networked applications*
• Six hour reserve prevents the need to reprogram day/time on programmable models after a power outage
Heat Pump Model Specific Features
• Selectable single or dual stage compressor stages
• High balance point locks out auxiliary heating when outside air temperature is above set value, low balance
point locks out heat pump compressor operation when outside air temperature is below the set value
• Comfort/economy mode maximizes heat pump use before turning on auxiliary heating
• Compressor/auxiliary interlock adds flexibility by locking out heat pump operation during auxiliary heating
to prevent high pressure trip when the coil is downstream of the auxiliary heat source
* Use programmable models only when installing as standalone thermostats that may eventually be added to a WEBs-
AX network. When a programmable thermostat is added to a network, schedules should be applied through the
WEBStation-AX.
TB7600 Series Model Selection
Product Number
Description
Outputs Scheduling
1
Occupancy
Sensor
2
BACnet Models
TB7600A5014B
Single Stage RTU
1H/1C
No
TB7600A5514B
Single Stage RTU
1H/1C
No
X
TB7600B5014B
Multi-stage RTU
2H/2C
No
TB7600B5514B
Multi-stage RTU
2H/2C
No
X
TB7600H5014B
Heat Pump
3H/2C
No
TB7600H5514B
Heat Pump
3H/2C
No
X
TB7605B5014B
Economizer RTU
2H/2C
No
TB7605B5514B
Economizer RTU
2H/2C
No
X
TB7652A5014B
Single Stage RTU
1H/1C
Yes
TB7652A5514B
Single Stage RTU
1H/1C
Yes
X
TB7652B5014B
Multi-stage RTU
2H/2C
Yes
TB7652B5514B
Multi-stage RTU
2H/2C
Yes
X
TB7652H5014B
Heat Pump
3H/2C
Yes
TB7652H5514B
Heat Pump
3H/2C
Yes
X
TB7656B5014B
Economizer RTU
2H/2C
Yes
TB7656B5514B
Economizer RTU
2H/2C
Yes
X
Wireless Models
TB7600A5014W
Single Stage RTU
1H/1C
No
TB7600A5514W
Single Stage RTU
1H/1C
No
X
TB7600B5014W
Multi-stage RTU
2H/2C
No
TB7600B5514W
Multi-stage RTU
2H/2C
No
X
TB7600H5014W
Heat Pump
3H/2C
No
TB7600H5514W
Heat Pump
3H/2C
No
X
TB7605B5014W
Economizer RTU
2H/2C
No
TB7605B5514W
Economizer RTU
2H/2C
No
X
TB7652A5014W
Single Stage RTU
1H/1C
Yes
TB7652A5514W
Single Stage RTU
1H/1C
Yes
X
TB7652B5014W
Multi-stage RTU
2H/2C
Yes
TB7652B5514W
Multi-stage RTU
2H/2C
Yes
X
TB7652H5014W
Heat Pump
3H/2C
Yes
TB7652H5514W
Heat Pump
3H/2C
Yes
X
62-2016.fm Page 2 Thursday, April 14, 2011 1:40 PM