WIRING

One Motion Light

Twist the junction box wires and the
fixture wires together as shown below.
Secure with wire connectors. If you have
a metal junction box, you may not need
the green “pigtail”. If you are unsure about
the grounding method, consult your local
building code.

Two Motion Lights

Black

White

Green

or Bare

Light

Fixture

Black

White

Green

or Bare

Light

Fixture

Light

Fixture

CAUTION: DO NOT connect the RED

wire unless you want to control other
lights from the motion sensor.

Note: All wiring should be run in accordance
with the National Electrical Code through
conduit or another acceptable means.
Contact a qualified electrician if there is
any question as to the suitability of the
system.

Connect the fixture wires to the wires in the
junction box. Twist the wires together and
secure with wire connectors.

Black to black

White to white

Recommended Grounding Method

Use a green ground “pigtail” (not provided) and
twist one end together with the bare fixture wire
and the box ground wire. Secure with a wire
connector. Secure the other end of the “pigtail”
with the GND screw on the mounting plate.