Heat & Glo Fireplace ESCAPE 36DV User Manual
Page 18

Heat & Glo • Escape-36DV • 2012-900 • Rev. AB • 10/08
18
Figure 5.10
2. Top Vent - Vertical Termination - (continued)
Three Elbows
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
V
2
V
1
+ V
2
Minimum
H
1
+ H
2
Maximum
1-1/2 ft.
305 mm
2 ft.
610 mm
2 ft.
457 mm
2-1/2 ft.
762 mm
2-1/2 ft.
610 mm
5-1/2 ft.
1676 mm
3-1/2 ft.
914 mm
8-1/2 ft.
2591 mm
4-1/2 ft.
1219 mm
11-1/2 ft.
3505 mm
V
1
+ V
2
+ H
1
+ H
2
= 63 ft. (19.2 m) Maximum
H
1
+ H
2
= 23 ft. (7.1 m) Maximum
Note: Must have a 12 inches
minimum vertical vent before
attaching any elbow to the unit.
See also other documents in the category Heat & Glo Fireplace Kiln:
- 6000GCF-IPI (57 pages)
- Heat-N-Glo 6000XLS (43 pages)
- ST-HV-IPI (45 pages)
- 8000CL-IPI-T (82 pages)
- SL-750TV-IPI-E (47 pages)
- CFL-24LP-B (21 pages)
- HEAT & GLOW XLR-PB-AU (70 pages)
- VRT-BZ-N-AUB (76 pages)
- 6000TRS-CE (45 pages)
- SL-42 DVT (46 pages)
- CRESTFIRE CF550ENH (26 pages)
- EM-485T - 42 (53 pages)
- CRESCENT II (54 pages)
- CRESCENT II (52 pages)
- Heat & Glo Gas Fireplace ESC-42ST (68 pages)
- XLR-PLUS-N-AU (77 pages)
- RUTHERFORD 50 (48 pages)
- CF230E-B (24 pages)
- HEAT & GLO CF550E-B (26 pages)
- Heat & Glo 6000GL-IPI-S (67 pages)
- GRAND-I35 (43 pages)
- RED40 (78 pages)
- LCOR-HV-IPI (46 pages)
- Heat & Glo Fireplace 6000C (86 pages)
- 6000TR-OAK-IPI (31 pages)
- Heat & Glo Cosmo-130 (35 pages)
- 6000TV-OAK-IPI (20 pages)
- ST-38GTV (18 pages)
- CERONA-36 (65 pages)
- PIER-TVFL st-42tvfl (25 pages)
- 2197-980 (69 pages)
- Heat & Glo Fireplace AT-GRAND (23 pages)
- Heat-n- Glo BE-41 (31 pages)
- XLR-PB-CE (65 pages)
- EM-485T (52 pages)
- SL-550TV-D (43 pages)
- EVEREST (27 pages)
- HEAT & GLO SL-550 (1 page)
- HEAT & GLO TWILIGHT-II (37 pages)
- EXCLAIM-36H-C (46 pages)
- Heat & Glo 550TRSI-AUF (80 pages)
- Soho24B 2137-900 (55 pages)
- HEAT & GLO BAY-40 (52 pages)
- 8000CFLP-OAKIPI (58 pages)
- HEAT & GLO Escape-42DVLP (61 pages)