beautypg.com

Removing the access panel, Installing the access panel – HP SAS DL360 User Manual

Page 26

background image

26

HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide

b. Secure the server by tightening the thumbscrews.

6. Reconnect the peripheral cables and power cords.

Removing the access panel

WARNING: To reduce the risk of personal injury from hot

surfaces, allow the drives and the internal system components to
cool before touching them.

CAUTION: Do not operate the server for long periods without

the access panel. Operating the server without the access panel results
in improper airflow and improper cooling that can lead to thermal
damage.

1. Power down the server if the standard cable management solution is installed

("Powering down the server" on page

24

).

NOTE: If the optional cable management arm is installed, you can
extend the server and perform hot-plug installation or maintenance
procedures without powering down the server.

2. Extend the server from the rack, if applicable ("Extending the server from the

rack" on page

25

).

3. Lift up on the hood latch handle and remove the access panel.

Installing the access panel

1. Place the access panel on top of the server with the hood latch open. Allow

the panel to extend past the rear of the server approximately 8 mm (0.2 in).

2. Engage the anchoring pin with the corresponding hole in the latch.

3. Push down on the hood latch. The access panel slides to a closed position.

This manual is related to the following products: