598-1160-03
Mount the Light Control
❒
Place the mounting bolt through the front of the
junction box cover. Push the small gasket hole over
the mounting screw.
❒
Make sure the wire connectors and wires are inside
the junction box. Align the mounting screw with the
center hole in the mounting strap. Secure the fixture
to the mounting strap.
❒
Push the rubber plug firmly into place.
❒
If not installed on a weatherproof box,
caulk the
wall plate and mounting surface with silicone
❒
Adjust the bulb holders by loosening the lock nuts
but do not rotate the bulb holders more than 180°
from the factory setting.
Keep bulbs at least 1" (25
mm) from the sensor.
Wire the Light Control
Push the rubber plug
over the mounting screw.
White to
White
Black to
Black
Gasket
Mounting
Strap
Mounting
Bolt
Rubber
Plug
Connect any fixture ground wire(s) and the cover
plate ground screw to the junction box ground
wire.
WARNING: Turn power off at circuit breaker
or fuse.
❒
Remove the existing light fixture.
❒
Install mounting strap to junction box using screws
appropriate for your junction box.
❒
The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of
the cover plate. The small end then goes into one
of the slots on the mounting strap.
❒
Thread all fixture wires through the large holes in
the gasket as shown.
❒
Connect the junction box wires to the light fixture
wires as shown. Twist together and secure with
wire connectors.