Single step trace & last information display – Epson S1C62 Family User Manual
Page 179

Format
ICE CONTROL SOFTWARE ICS62XX
S1C62 FAMILY
EPSON
VIII-65
DEVELOPMENT TOOL REFERENCE MANUAL
SINGLE STEP TRACE & LAST INFORMATION DISPLAY
U
Function
#U,
,
#U,,
<
step number>
Executes trace and single step actions of programs and indicates final results alone.
(1) The target program is executed from the address specified in for the frequency
specified in
displayed until after the final instruction is completed.
(2) When the is defaulted, execution starts from the current PC for the specified
number of steps.
Examples
#U,100,5
*PC=01AA IR=ADI OR A,B A=5 B=0 X=04F T=03F F=ID.C SP=13
#U,,1
*PC=01AB IR=FFF NOP7 A=5 B=0 X=04F Y=03F F=ID.C SP=13
#
(1) The U command does not run in real time, so the target timer is renewed. (For details
refer to Section 2.3.13, "Limitations during emulation".)
(2) When the H command is input after executing this command, the message,
*NO HIS-
TORY DATA*
, is displayed. Therefore, the G command must be used to analyze history
data.
Notes