Function
SET DATA RAM
SD
#SD,
(With guidance)
Contents of the data RAM area are displayed or modified.
(1) Data cannot be written to the read only area.
(2) Data in the write only area cannot be read.
#SD,20
20 5:A
...
Contents of address 20 are modified and stored to A
21 5:^
...
Return to previous address (one less than the current
20 A:B
address) by entering ^
21 5:F
22 5:/
...
Instruction terminated by /
#SD,FFF
* COMMAND ERROR *
...
When specification exceeds the maximum value of the
RAM area (7F for S1C6S3N7/66S3B7/6S3L7), an
error is indicated
#SD,70
70 4:-
71 F:-
...
Hyphen only displayed due to read only address;
72 5:-
data input not accepted
73 6:-
74 6:5
75 8:4
76 5:A
77 8:9
78 8:5
79 A:-
7A B:-
: : :
7E F:-
...
Command terminates after last address entered
#SD,E50
* UNUSED AREA *
...
When an unused area has been specified, "UNUSED
AREA" is displayed (for S1C6S460)
#SD,ECE
ECE 0:F
ECF 4:F
* UNUSED AREA *
...
When an unused area is entered into during data setting,
"UNUSED AREA" is displayed (for S1C6S460)
Examples