Format

ICE CONTROL SOFTWARE ICS62XX

S1C62 FAMILY

EPSON

VIII-47

DEVELOPMENT TOOL REFERENCE MANUAL

SET MX, MY DATA

SXY

#SXY

(With guidance)

Examples

Function

Instruction will not complete with / input; use up to the last register.
Current contents of the X register (Xp, Xh, Xl), Y register (Yp, Yh, Yl), and MX and MY

(contents specify memory X, Y) are displayed. Contents of MX and MY can also be modified.

#SXY

...

Display only;

alone continues operation

X=040 MX=5:
Y=030 MY=A:

#SXY
X=040 MX=5:0

...

Sets new data to MX, MY

Y=030 MY=A:F

#SXY
X=070 MX=3:-

...

Data to read only area not accepted

Y=FFF MY=-:OV

...

Input not accepted if RAM area is exceeded

#SXY
X=E52 MX * UNUSED AREA *

...

An unused area error message is displayed

Y=1A7 MY=1:3