beautypg.com

Ba, bar, Set/reset break address condition – Epson S1C62 Family User Manual

Page 166

background image

Format

ICE CONTROL SOFTWARE ICS62XX

VIII-52

EPSON

S1C62 FAMILY

DEVELOPMENT TOOL REFERENCE MANUAL

Function

BA, BAR

SET/RESET BREAK ADDRESS CONDITION

#BA,

,

,

,

#BAR,

,

,

,

Sets break condition for the PC.

(1) BA:

The value indicated at the specified

is set to the break condition.
Multiple addresses are set by using commas to divide them. Consecutive ad-
dresses are set by separating entries with two period marks (.). Entering 3>..
sets a break condition such that

PC

.

(2) BAR: Can be cleared separately from break condition set by BA.

(3) Addresses which can be entered by a single BA or BAR instruction can be set multiple

times in a single line (80 columns).

(4) When the BA command is executed several times, previous settings are valid.

(5) When the BM command is executed, all BA conditions are canceled.

(6) When entering the GO command at a break, the BA condition may enter the clear mode

or a condition retaining mode. (Refer to the BRKSEL command.)

Examples

#BA,100,200,101,1FF

...

Break condition set at addresses 100, 200, 101 and 1FF

#BA,300..3FF

...

Break conditions set at addresses 300 to 3FF

#BAR,100,200..3FF

...

Break conditions canceled at address 100 and addresses
200 to 3FF (although break conditions were not set at
addresses 201 to 2FF, no error occurs even with BAR
setting)

#BC
BA 0201

...

BA condition is displayed by BC command

BA 02FF
BD NONE
BR NONE
:
#