Setting the Operation Mode

26

MODE SW 5

This specifies the frame rate of output.

OFF

59.94 Hz

ON

50 Hz

MODE SW 6/7

This specifies the output resolution.

6

OFF

7

OFF

Output at SD resolution

6

ON

7

OFF

Output at 1280 x 720 progressive resolution

6

OFF

7

ON

Output at 1920 x 1080 interlaced resolution

6

ON

7

ON

Output at 1920 x 1080 progressive resolution

MODE SW 8

This specifies the setup level for composite input and SD component input.

* This is valid only for NTSC input and 480i input.

OFF

Used mainly in Japan

ON

Used mainly in NTSC regions other than Japan

MODE SW 9

This specifies the type of 3G-SDI output coming out from the SDI OUT connector.

* The signal type of SDI IN is detected automatically.

OFF

Output with Level A mapping structure

ON

Output with Level B mapping structure

MODE SW 10

This specifies the control mode.

* This also enables/disables the AUTO OFF function (p. 12).

OFF

Mode is controlled by switches 1–9.

ON

The unit operates according to the settings in the internal memory (Set with VC-1 RCS software).