Other features, About the tally/gpio connector, Operating a visca-compatible video camera – Roland V-1200HD Multi-Format Video Switcher User Manual
Page 29: By remote control 29, About the tally/gpio connector 29, P. 29, Rs-422 connector specifications, Tally/gpio connector specifications
29
Operating a VISCA-Compatible Video
Camera by Remote Control
You can connect a VISCA-compatible video camera to the RS-422
connector and operate the camera remotely from the V-1200HD.
For more information on how to do this, refer to the “V-1200HDR/
V-1200HD RCS Remote Control Guide” (PDF) available for download
at the Roland website.
Roland website
http://proav.roland.com
RS-422 Connector Specifications
5 4 3 2 1
9 8 7 6
D-Sub 9-pin (female)
Pin No.
Signal name
1
GND
2
TxD-
3
RxD+
4
GND
5
NC
6
GND
7
TxD+
8
RxD-
9
GND
Transmission method
Start-stop synchronization
(asynchronous mode), full-duplex
Communication speed
(baud rate)
9600 bps/38400 bps
Parity
None
Data length
8 bits
Stop-bit length
1 bit
Flow control
None
About the TALLY/GPIO Connector
The V-1200HD is equipped with a D-Sub 25-pin TALLY/GPIO
connector. In addition to tally input/output functions, this provides
functionality for control signal input and output, and you can use
it to transmit and receive control signals between the unit and an
external device.
TALLY/GPIO Connector Specifications
5
Tally/control output connector specifications
Maximum input: 12 V/200 mA
Open-collector type
5
Control input connector specifications
Trigger method: No-voltage contact (make-contact)
triggeringContact capacity: DC 24 V 0.1 A or higher
Input method: Photocoupler
D-Sub 25-pin (female)
1
13
14
25
* By default, the following functions are assigned to the
V-1200HD’s TALLY/GPIO connector.
Pin number
Connector name
Function
Default
1
OUTPUT 1/GPO 1
Tally output/
control output
SDI 1 PGM
2
OUTPUT 2/GPO 2
SDI 1 PST
3
OUTPUT 3/GPO 3
SDI 2 PGM
4
OUTPUT 4/GPO 4
SDI 2 PST
5
OUTPUT 5/GPO 5
SDI 3 PGM
6
OUTPUT 6/GPO 6
SDI 3 PST
7
OUTPUT 7/GPO 7
SDI 4 PGM
8
OUTPUT 8/GPO 8
SDI 4 PST
9
OUTPUT 9/GPO 9
SDI 5 PGM
10
OUTPUT 10/GPO 10
SDI 5 PST
11
OUTPUT 11/GPO 11
SDI 6 PGM
12
OUTPUT 12/GPO 12
SDI 6 PST
13
OUTPUT 13/GPO 13
SDI 7 PGM
14
OUTPUT 14/GPO 14
SDI 7 PST
15
OUTPUT 15/GPO 15
SDI 8 PGM
16
OUTPUT 16/GPO 16
SDI 8 PST
17
—
GND
COM(GND)
18
INPUT 1
Control input
N/A
19
INPUT 2
N/A
20
INPUT 3
N/A
21
INPUT 4
N/A
22
INPUT 5
N/A
23
INPUT 6
N/A
24
INPUT 7
N/A
25
INPUT 8
N/A
Memo
You can use the V-1200HDR or V-1200HD RCS to change the
function assignments. For information on how to make the
settings, refer to the “V-1200HDR/V-1200HD RCS Remote Control
Guide” (PDF) available for download at the Roland website.
Roland website
http://proav.roland.com
Other Features