Setting port 0 configuration jumpers – ProSoft Technology 5205-DFNT-PDPS User Manual
Page 9
![background image](https://www.manualsdir.com/files/866184/content/doc009.png)
Start Here
PDPS ♦ ProLinx Gateway
PROFIBUS DP Slave
ProSoft Technology, Inc.
Page 9 of 61
December 31, 2008
1.3
Setting Port 0 Configuration Jumpers
Before installing the module on the DIN rail, you must set the jumpers for the Port
0 application port.
Note: Ethernet-only ProLinx modules do not use the serial port jumper settings. The serial
configuration jumper settings on an Ethernet-only module have no effect.
Note: The presence of Port 0 depends on the specific combination of protocols in your ProLinx
module. If your module does not have a Port 0, the following jumper settings do not apply.
Port 0 is preconfigured for RS-232. You can move the port configuration jumper
on the back of the module to select RS-485 or RS-422.
The following illustration shows the jumper positions for Port 0:
ProLinx 5000/6000 Series Module