10.2.4 FOR-TO- (STEP)-NEXT

Sets up a control loop.

Syntax:
FOR [expr1] TO [expr2] STEP [expr3]
..
..
..
NEXT [expr5]

Example:

10 FOR A=0 TO 10 STEP 2
20 PRINT A
30 NEXT A
40 PRINT "END OF LOOP"

Result:

0
2
4
6
8
10
END OF LOOP

10.2.5 GOTO

Use the GOTO statement to force the BASIC program to jump to a specific line

number.

Syntax:
GOTO [line number]

Example:

10 PRINT "ENTER A NUMBER"
20 INPUT A
30 IF A>0 THEN GOTO 40 ELSE GOTO 60
40 PRINT "NUMBER IS POSITIVE"
50 GOTO 70
60 PRINT "NUMBER IS NEGATIVE"
70 END

10.2.6 END

Use END to terminate the program execution.