Terminal block for I/O connectors:

Name Pin

Function

GND 1

Digital input 4

2

Digital input 3

3

Digital input 2

4

Digital input 1

5

Four sets of Digital Input, DI1 until DI4; the internal device

is also photo-coupled electrical relay. In practice, the

external device can be simply an On/Off switch. Four sets

of On/Off switch can be connected as different trigger

source.

DO_NO 6

DO_COM 7

Digital output implementation; Pin6 to COM (Pin7) is a

Photo-coupled relay on Normal Open status. External

device can directly connect to the terminals. However the

current that will go through the 2 nodes must not exceed

130mA. An external “Relay” can also be connected to the

terminals as an implementation. In this case, current

(or/and voltage) limitation is specified by the external

Relay.