beautypg.com

Appendix f, Troubleshooting & frequently asked questions – PLANET ICA-HM830W User Manual

Page 74

background image

8B

Appendix F:

Troubleshooting & Frequently Asked Questions

Features

The video and audio codec is

adopted in the device.

The device utilizes H.264 and M-JPEG triple compression to

providing high quality images. Where H.264 is standards for video

compression and M-JPEG is a standard for image compression.
The audio codec is defined as u-Law for RTSP streaming.

The maximum number of user

access device simultaneously.

The maximum number of users is limited to 10. However, it also

depends on the total bandwidth accessed to this device from clients.

The maximum data throughput of the device is around 20~25Mbps

for UDP mode and 10Mbps for HTTP mode. Therefore, the actual

number of connected clients is varying by streaming mode, settings

of resolution, codec type, frame rate and bandwidth. Obviously, the

performance of the each connected client will slow down when many

users are logged on.

The device can be used outdoors

or not.

The device is not weatherproof. It needs to be equipped with a

weatherproof case for outdoors using. However, equipped with a

weatherproof case might disable the audio function of the device.

Install this device

Status LED does not light up.

Check and confirm that the DC power adaptor, included in

packaged, is used. Secure the power connector and re-power it on

again.

The network cabling is required for

the device.

The device uses Category 5 UTP cable allowing 10 and/or 100

Base-T networking.

The device will be installed and

work if a firewall exists on the

network.

If a firewall exists on the network, port 80 is open for ordinary data

communication. The HTTP port and RTSP port need to be opened

on the firewall or NAT router.

The username and password for

the first time or after factory default

reset

Username = admin and leave password = admin.
Note that it’s all case sensitivity.

Forgot the username and

password

Follow the steps below.
1. Restore the factory default setting by press and holding down

more than 20 seconds on the device.

2. Reconfigure the device.

Forgot the IP address of the

device.

Check IP address of device by using the IPInstaller program or by

UPnP discovery or set the device to default by Reset button.